Compatibility
This page covers what works with the J1600: the two charger options and the pallets and load carriers the vehicle can handle.
Charger compatibility
Both chargers work with the J1600's 24 V, 200 Ah lithium-iron-phosphate (LiFePO4) battery:
- The manual charger (€3,600 list) is plugged in by the operator.
- The automatic charger (€8,400 list) docks with the automatic-charging interface and charging plates that are part of every J1600.
Charging adds approximately 47 percentage points of charge per hour with either option.
Pallet and load-carrier compatibility
The J1600 requires an open-base carrier with no bottom deck board so its forks can enter.
| Parameter | Limit or support |
|---|---|
| Maximum pallet/load length, including overhang | 1,250 mm / 49 in |
| Maximum pallet/load width, including overhang | 1,250 mm / 49 in |
| Maximum load height from floor | 1,700 mm / 67 in |
| Maximum rated payload | 1,600 kg / about 3,500 lb |
| EPAL support | EPAL Euro Pallet, EPAL 3, EPAL 6 |
| GMA support | All GMA pallets with an open base |
| Custom carriers | Any forkable open-base carrier within the size limits |
Supported carriers go beyond Euro pallets: open cages, barrels, sensitive loads, and other custom open-base carriers all qualify when they fit the envelope. Compatibility in practice depends on base geometry, size, load stability, and operator judgment — there is no blanket approval covering every carrier or hazardous material.
Dual mode lets the operator handle sensitive or unstable loads — such as barrels or poorly stacked pallets — manually during pickup and close maneuvering, then hand the long transport leg to autonomous mode.
Fork and vehicle geometry
Fork length is 1,150 mm, fork width 180 mm, fork outer distance 680 mm, and fork inner distance 320 mm. The full dimension set is on the technical specifications page.
Operating limits
Autonomous operation is indoor and level-floor (0% automatic gradeability), with an operating temperature of 5–40°C and IP21 ingress protection. See technical specifications for the complete environment requirements.